Qeehua Stainless Steel Magnetic Pumps
Qeehua Parameter Table
| Model | Diameter | Motor | Max. Head (m) | Max. Capacity (m³/h) | Weight (kg) | ||||
|---|---|---|---|---|---|---|---|---|---|
| Inlet | Outlet | KW | HP | 50Hz | 60Hz | 50Hz | 60Hz | ||
| QWW32-25-1 | DN32 | DN25 | 0.75 | 1 | 18 | 20.7 | 15 | 17.3 | 28 |
| QWW32-25-2 | DN32 | DN25 | 1.5 | 2 | 20 | 23 | 18 | 20.7 | 30 |
| QWW50-32-3 | DN50 | DN32 | 2.2 | 3 | 32 | 36.8 | 30 | 34.5 | 42 |
| QWW50-32-4 | DN50 | DN32 | 3 | 4 | 37 | 42.6 | 32 | 36.8 | 45 |
| QWW50-40-5 | DN50 | DN40 | 4 | 5 | 35 | 40.3 | 45 | 51.8 | 60 |
| QWW50-40-6 | DN50 | DN40 | 4.5 | 6 | 37 | 42.6 | 45 | 51.8 | 67 |
| QWW50-40-7.5 | DN50 | DN40 | 5.5 | 7.5 | 37 | 42.6 | 46 | 52.9 | 88 |
| QWW50-40-10 | DN50 | DN40 | 7.5 | 10 | 43 | 49.5 | 54 | 62.1 | 116 |
| QWW50-40-15 | DN50 | DN40 | 11 | 15 | 48 | 55.2 | 56 | 64.4 | 145 |
| Model | Diameter | Motor | Performance (50Hz) | Weight (kg) | |||
|---|---|---|---|---|---|---|---|
| Inlet | Outlet | KW | HP | Max. Head (m) | Max. Flow (L/min) | ||
| QWH20-15-05 | DN20 | DN15 | 0.37 | 0.5 | 50 | 35 | 11 |
| QWH20-15-07 | DN20 | DN15 | 0.5 | 0.7 | 80 | 45 | 12 |
| QWH25-20-1 | DN25 | DN20 | 0.75 | 1 | 60 | 50 | 16 |
| QWH25-20-1.5 | DN25 | DN20 | 1.1 | 1.5 | 80 | 65 | 18.5 |
| QWH40-32-2 | DN40 | DN32 | 1.5 | 2 | 90 | 90 | 26 |
| QWH40-32-3 | DN40 | DN32 | 2.2 | 3 | 100 | 120 | 29 |
| QWH40-32-4 | DN40 | DN32 | 3 | 4 | 120 | 160 | 37 |
| QWH50-40-5.5 | DN50 | DN40 | 4 | 5.5 | 65 | 195 | 67 |
| QWH50-40-7.5 | DN50 | DN40 | 5.5 | 7.5 | 80 | 225 | 69 |
| Model | Diameter | Motor | Max. Head (m) | Max. Capacity (L/min) | Weight (kg) | ||||
|---|---|---|---|---|---|---|---|---|---|
| Inlet | Outlet | KW | HP | 50Hz | 60Hz | 50Hz | 60Hz | ||
| QWC15-018 | DN15 | DN15 | 0.18 | 0.24 | 15 | 17.3 | 15 | 17.3 | 7.5 |
| QWC15-025 | DN15 | DN15 | 0.25 | 0.33 | 20 | 23 | 15 | 17.3 | 9 |
| QWC15-037 | DN15 | DN15 | 0.37 | 0.5 | 30 | 34.5 | 30 | 34.5 | 9.5 |
| QWC15-05 | DN15 | DN15 | 0.5 | 0.7 | 40 | 46 | 38 | 43.7 | 10 |
| QWC20-075 | DN20 | DN20 | 0.75 | 1 | 45 | 51.8 | 45 | 51.8 | 10 |
| QWC20-11 | DN20 | DN20 | 1.1 | 1.5 | 60 | 69 | 60 | 69 | 17 |
| QWC25-17 | DN25 | DN25 | 1.7 | 2.3 | 65 | 74.8 | 90 | 103.5 | 22 |
| QWC25-25 | DN25 | DN25 | 2.5 | 3.3 | 90 | 103.5 | 95 | 109.3 | 26 |
| QWC25-30 | DN25 | DN25 | 3 | 4 | 100 | 115 | 110 | 126.5 | 35 |
| QWC32-40 | DN32 | DN32 | 4 | 5 | 90 | 103.5 | 200 | 230 | 55 |
| Model | Motor | Max. Head (m) | Max. Capacity (m³/h) | Voltage (V) | Weight (kg) | |||
|---|---|---|---|---|---|---|---|---|
| KW | HP | 50Hz | 60Hz | 50Hz | 60Hz | |||
| QLL32-1 | 0.75 | 1 | 16 | 18.4 | 12 | 13.8 | 380 | 40 |
| QLL32-2 | 1.5 | 2 | 25 | 28.8 | 18 | 20.7 | 380 | 43 |
| QLL40-3 | 2.2 | 3 | 28 | 32.2 | 24 | 27.6 | 380 | 48 |
| QLL50-4 | 3 | 4 | 28 | 32.2 | 30 | 34.5 | 380 | 60 |
| QLL40-5 | 4 | 5 | 32 | 36.8 | 40 | 46 | 380 | 71 |
| QLL50-7.5 | 5.5 | 7.5 | 40 | 46 | 80 | 92 | 380 | 90 |
| QLL40-10 | 7.5 | 10 | 42 | 48.3 | 90 | 103.5 | 380 | 104 |
| QLL65-15 | 11 | 15 | 46 | 52.9 | 120 | 138 | 380 | 160 |
| QLL80-20 | 15 | 20 | 52 | 59.8 | 140 | 161 | 380 | 175 |
| QLL80-25 | 18.5 | 25 | 85 | 97.8 | 150 | 172.5 | 380 | 221 |
| QLL80-30 | 22 | 30 | 80 | 92 | 165 | 189.8 | 380 | 238 |
Not sure how to choose?
Our professional technicians will give you advice in 2 business hours. 👉
If you are unsure which product you need, we will recommend the most cost-effective series based on your requirements.
Confused about choosing a product?
-
Bottom Circulation: Bottom-mounted pumps for chemical recycling.
-
Precision Dosing: Top-tier piping for accurate spray delivery.
-
System Integration: Hidden pump units driving automated flow.
-
Easy Maintenance: Accessible design for streamlined site servicing.
-
Power Core: Dense pump arrays driving long-line operations.
-
Electrolytic Feed: Pumps electrolytes into acid processing tanks.
-
External Filtration: Bottom pumps drive liquid through impurity filters.
-
Oxidation Side-view: Maintains chemical uniformity via pump-rectifier coordination.
-
Precision Filtering: Specialized units for high-purity plating solutions.
-
Continuous Loop: Pressure-monitored arrays ensuring PCB surface flatness.
-
Corrosive Handling: Reinforced vertical pumps for high-temp media.
-
Dosing Maintenance: Tuning pumps for acid-base neutralization.
-
Centralized Transfer: Arranged units for long-distance blending.
-
Gallery Transport: Protected pumps for wastewater collection.
-
Quantitative Dosing: Precise injection from PE storage tanks.
-
Dosing Station: Multi-pump systems for waste neutralization.
-
Gas Scrubbing: Circulating liquids to neutralize exhaust.
-
Precision Dosing: Compact pumps for lab-grade chemical delivery.
-
Power Unit: Industrial anti-corrosion pumps for acid-base handling.
Application Consulting For Your Needs
consideration. Our team of experts will provide one-on-one technical consultation to help you find and implement a customized solution that suits your application needs.
We will provide different solutions based on your project within 2 business hours.